 CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, PUSH BUTTON GERATESCHUTZSCHALTER, 2POLIG, DRUCKTASTENBETATIGT
Product description
The 2 pole, push button actuated version of the TA45 line of thermal CBE's can be used for various purposes. Basically it is a CBE for automatic interruption of overloads with facilities for regular manual ON/OFF switching operations under normal load conditions. It is capable of interrupting moderate short circuit currents without the aid of back-up protection. A special version is available as a CBE-switch, in which the means for automatic overcurrent interruption (the bimetal relases), are omitted. Another available version of this line utilizes an under-voltage release to protect persons against injuries caused by unexpected events like the automatic restarting of motors after a power failure. This release can be combined with the thermal release required for overcurrent protection. Protection against injuries is also provided by another CBE of this line, which prevents the starting of a machine should a protective cover be removed from dangerous parts of the machine.
TA45
Produktebeschreibung
Die 2polige, drucktastenbetatigte Version der TA45-Linie ist ein thermischer Gerateschutzschalter, kurz CBE (Circuit Breaker for Equipment) genannt, der fur viele Zwecke eingesetzt werden kann. In seiner Grundausfuhrung ist dieser CBE fur die automatische Unterbrechung von Uberlast-Stromen und das manuelle Wiedereinschalten resp. fur manuelles EIN/AUS-Schalten im Normalbetrieb bestimmt. Der CBE ist in der Lage, Uberstrome bis zu seinem Schaltvermogen ohne back-up Unterstutzung zu unterbrechen. Eine spezielle Version ist erhaltlich als CBE-switch. Bei dieser Ausfuhrung fehlt der Thermo-Ausloser. Eine weitere Version der TA45-Linie ist mit Unterspannungsauslosung ausgerustet. Diese schutzt Personen vor moglichen Verletzungen wie sie z.B. durch unbeabsichtigtes Wiederanlaufen von Geraten nach einem Netzausfall verursacht werden konnten. Dieser Schutz kann mit dem thermischen Uberlast-Schutz kombiniert werden. Schutz gegen Verletzungen wird auch gewahrleistet durch eine weitere Version der TA45-Reihe, die den Anlauf einer Maschine verhindert, bei der eine wichtige Schutzabdeckung fehlt.
Available options * CBE for overcurrent protection 1 or 2 protected poles (thermal) * CBE with undervoltage release: The CBE will open automatically when the voltage drops below the trip level. Only when the supply voltage has reached the reset level, the CBE can be reclosed manually. * CBE switch with mechanical lock-out latch: A spring loaded pin will trip the CBE if a protective cover of the equipment is removed. The CBE can not be switched ON until the protective cover is refitted. * CBE with remote trip release: The remote trip release permits the CBE to be tripped by a external contact (sensor) energizing the trip coil. * CBE with auxiliary contact: All types of the line can be outfitted with an auxiliary contact (changeover contact). TA45 is positively trip-free. The rated current range is 0,05 to 20 A at AC 240 V / DC 60 V . The CBE comes with snap-in mounting or flange mounting. A locking device suitable for padlocks prevents unauthorized switching ON of the CBE. The TA45 is approved in all major industrial countries and complies with the CBE-standard EN60934. In conjunction with its accessories the TA45 product line of Schurter paves the way for new unconventional applications.
Erhaltliche Versionen * Gerateschutzschalter mit Uberstromauslosung: Ein- oder zweipolig geschutzt durch Thermo-Bimetall * Gerateschutzschalter mit Unterspannungsausloser: Wiederanlaufschutz bei Spannungsausfall. Nach Unterschreiten der Abfallspannung (Netzausfall) springt der Gerateschutzschalter in die AUS-Stellung. Ein manuelles Einschalten ist erst dann moglich, wenn die wiederkehrende Spannung den Anzugswert des Auslosers erreicht. * Gerateschutzschalter mit mechanischer Schaltsperre: Ein unter Federdruck stehender Stift bewirkt ein automatisches Auslosen, falls die Schutzabdeckung entfernt wird. Ein Wiedereinschalten in dieser Position ist nicht moglich, solange die Abdeckung fehlt. * Gerateschutzschalter mit Fernauslosung: Der Fernausloser ermoglicht das Ausschalten durch einen externen Schalter oder Sensor, der die Auslosespule aktiviert. * Gerateschutzschalter mit Hilfskontakt: Alle Typen sind mit einem Hilfskontakt (Wechselkontakt) erhaltlich. Der TA45 ist positiv freiauslosend. Sein Nennstrombereich betragt 0,05 bis 20 A bei AC 240 V / DC 60 V . Die Montage erfolgt mittels Schnappbefestigung oder Flanschbefestigung. Mit einer zusatzlichen Abschliessvorrichtung fur ein Vorhangeschloss lasst sich der TA45 gegen unbefugtes Einschalten sichern. Der TA45 ist in den wichtigsten Industrielandern approbiert und entspricht der neuen CBE Europa Norm EN60934. In Verbindung mit dem vielfaltigen Zubehor ermoglicht der 2polige drucktastenbetatigte TA45 von Schurter neue, unkonventionelle Anwendungen.
Applications * * * * Motors Power supplies Processing machines etc.
Anwendungen * * * * Motoren Netzgerate Be- und Verarbeitungsmaschinen usw.
70
www.schurter.com
CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, PUSH BUTTON GERATESCHUTZSCHALTER, 2POLIG, DRUCKTASTENBETATIGT
Effect of ambient temperature
The unit is calibrated for an ambient temperature of +23C. To determine the rated current for a lower or higher ambient temperature, use a correction factor from the table below:
TA45
Einflu der Umgebungstemperatur
Die Eichung gilt fur eine Umgebungstemperatur von +23C. Zur Bestimmung des Nennstromes fur eine tiefere oder hohere Umgebungstemperatur ist ein Korrekturfaktor gema untenstehender Tabelle zu verwenden: *Umgebungstemperatur [C] -10 -5 0 +23 +30 +40 +55 Korrekturfaktor
*Ambient temperature [C] -10 -5 0 +23 +30 +40 +55
Correction factor
0,89 0,91 0,92 1,00 1,03 1,08 1,16
0,89 0,91 0,92 1,00 1,03 1,08 1,16
Example Rated current at +23C Ambient temperature Correction factor Chosen rated current at +40C ambient temperature 5 A x 1,08 = 5,5 A
5,0 A +40C 1,08
Beispiel Nennstrom bei +23C Umgebungstemperatur Korrekturfaktor Gewahlter Nennstrom bei +40C Umgebungstemperatur 5 A x 1,08 = 5,5 A
5,0 A +40C 1,08
* Temperature must be measured at the rear of the breaker next to the terminals after equipment operating temperature has been reached.
* Die Temperatur wird in der Nahe der Schalteranschlusse ermittelt, nachdem das zu schutzende System seine Arbeitstemperatur erreicht hat.
Tripping characteristics Auslosekennlinien In <3 A
[ min ] [ sec ] 10'000
Type / Typ Rated current Nennstrom TA45 In <3 A 1 pole protected 1polig geschutzt 2 pole protected 2polig geschutzt +23 C
Tripping characteristics Auslosekennlinien 3 A In <18 A
[ min ] [ sec ] 10'000
Type / Typ Rated current Nennstrom TA45 3 A In <18 A 1 pole protected 1polig geschutzt 2 pole protected 2polig geschutzt +23 C
Tripping characteristics Auslosekennlinien In 18 A
[ min ] [ sec ] 10'000
Type / Typ Rated current Nennstrom TA45 In 18 A 1 pole protected 1polig geschutzt 2 pole protected 2polig geschutzt +23 C
60 30 20 10 5 200 100 1 50 2000 1000 500
60 30 20 10 5 200 100 1 50 2000 1000 500
60 30 20 10 5 200 100 1 50 2000 1000 500
Ambient temp. Umgebungstemp.
Ambient temp. Umgebungstemp.
Ambient temp. Umgebungstemp.
20 10 5 2 1 0,5 0,3 0,2 0,1 1,05 1,32 2 3 4 5 8 10
20 10 5 2 1 0,5 0,3 0,2 0,1 1,05 1,32 2 3 4 5 8 10
20 10 5 2 1 0,5 0,3 0,2 0,1 1,05 1,32 2 3 4 5 8 10
Tripping time / Auslosezeit
Tripping time / Auslosezeit
Multiple of rated current Nennstrom-Vielfaches
[ x In ]
Multiple of rated current Nennstrom-Vielfaches
Tripping time / Auslosezeit
[ x In ]
Multiple of rated current Nennstrom-Vielfaches
[ x In ]
www.schurter.com
71
CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, PUSH BUTTON GERATESCHUTZSCHALTER, 2POLIG, DRUCKTASTENBETATIGT
Technical data / Technische Daten
Rated voltage Ue Nennspannung Ue Rated current In Nennstrom In Conditional short circuit current Inc Bedingtes Schaltvermogen Inc Short circuit capacity Icn See approvals page 73 Siehe Approbationen Seite 73 See approvals page 73 Siehe Approbationen Seite 73 EN 60934, PC1, AC 240 V EN 60934, PC1, AC 240 V AC 240 V with In<3 A AC 240 V with In3 A DC 60 V with In<3 A DC 48 V with In 3 A AC 240 V bei In<3 A AC 240 V bei In3 A DC 60 V bei In<3 A DC 48 V bei In 3 A Accessible range With accessoris Terminal side With accessoirs Betatigungsbereich Mit Zubehor Anschlussbereich Mit Zubehor Accessible range Betatigungsbereich DC 500 V DC 500 V Number of cycles at In (AC 240 V; DC 60 V) Number of cycles at 6 x In (AC 240 V) Number of cycles at 4 x In (DC 60 V) Anzahl Schaltspiele bei In (AC 240 V; DC 60 V) Anzahl Schaltspiele bei 6 x In (AC 240 V) Anzahl Schaltspiele bei 4 x In (DC 60 V) (number of cycles: 3) (number of cycles: 3) (number of cycles: 3) (number of cycles: 3) (Anzahl Schaltspiele: 3) (Anzahl Schaltspiele: 3) (Anzahl Schaltspiele: 3) (Anzahl Schaltspiele: 3) AC 240 V; DC 60 V AC 240 V; DC 60 V
TA45
AC/DC 0,05 A - 20 A AC/DC 0,05 A - 20 A 1000 A 1000 A 10 In 300 A 10 In 120 A 10 In 300 A 10 In 120 A IP40 IP54, IP65 IP00 IP40 IP40 IP54, IP65 IP00 IP40 AC 4000 V AC 4000 V >100 M >100 M 50'000 x 40 x 40 x 50'000 x 40 x 40 x -10C to +55C -10C bis +55C
Schaltvermogen Icn
Degree of protection
Schutzklasse
Dielectric strength Spannungsfestigkeit Insulation resistance Isolationswiderstand Endurance
Lebensdauer
Permissible ambient temperature Zulassige Umgebungstemperatur Resistance to vibration Schwingungsfestigkeit Shock resistance Stossfestigkeit Type of tripping IEC 60068-2-6, test Fc, 0.75 mm amplitude 5-60 Hz, 60-500 Hz IEC 60068-2-6, Test Fc, 0.75 mm Amplitude 5-60 Hz, 60-500 Hz IEC 60068-2-27, test Ea IEC 60068-2-27, Test Ea * Thermal positively trip-free * Undervoltage release (Zero-voltage release) * Remote trip * Mechanical lock-out latch * Thermisch positive Freiauslosung * Unterspannungs-Auslosung (Zero-voltage release) * Fernauslosung * Mechanische Schaltsperre
10 g 10 g 30 g 30 g
Ausloseart
Weight Gewicht
approx. 35 g ca. 35 g
72
www.schurter.com
CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, PUSH BUTTON GERATESCHUTZSCHALTER, 2POLIG, DRUCKTASTENBETATIGT
Technical data (continued) / Technische Daten (Fortsetzung)
Auxiliary contact (changeover) / Hilfskontakt (Wechsler) Rated voltage Nennspannung Rated current Max. Nennstrom DC 28 V DC 28 V Max. 10 A resistive load Max. 10 A ohmsche Last DC 60 V DC 60 V max. 2 A resistive load max. 2 A ohmsche Last AC 240 V AC 240 V max. 2 A cos 0,7 max. 2 A cos 0,7
TA45
Undervoltage release / Unterspannungs-Ausloser Max. operating voltage Max. Betriebsspannung Rated operating voltage Ue Nennbetriebsspannung Ue Current consumption (10%) Stromaufnahme(10%) Highest reset level Hochste Wiedereinschaltspannung Lowest trip level Tiefste Abfallspannung Trip delay Ausschaltverzug Impuls withstand voltage (1,2 / 50 s) Stoss-Spannungsfestigkeit (1,2 / 50 s) Remote trip / Fern-Ausloser Permissible impuls duration of the make contact (no) Zulassige Impulsdauer des Schliesskontaktes Electrical load of the make contact (no) Elektrische Belastung des externen Schliesskontaktes 5V 5V 10,5 mA 10,5 mA 12 V 12 V 16,5 mA 16,5 mA 24 V 24 V 17,0 mA 17,0 mA 48 V 48 V 3,2 mA 3,2 mA 120 V 120 V 3,7 mA 3,7 mA 240 V 240 V 3,1 mA 3,1 mA 0,85 Ue 0,85 Ue 0,20 Ue 0,20 Ue 20 ms - 50 ms 20 ms - 50 ms 4 kV 4 kV 1,1 Ue 1,1 Ue
(Between terminal C and P1) (Zwischen den Anschlussen C und P1)
unlimited unbegrenzt
Current max. 12 mA / power max. 1,1 W Strom max. 12 mA / Leistung max. 1,1 W
Approvals / Approbationen
Rated current range Nennstrombereich AC UL UL 1077 0,05 - 20 A Rated voltage Nennspannung AC 240 V Rated voltage Nennspannung DC 60 V
CSA
CSA C22.2 235
0,05 - 20 A
240 V
60 V
DVE
VDE
EN 60934
0,05 - 20 A
240 V
60 V
SEMKO
EN 60934
0,05 - 20 A
250 V
60 V
SEV
EN 60934
0,05 - 20 A
240 V
60 V
www.schurter.com
73
CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, PUSH BUTTON GERATESCHUTZSCHALTER, 2POLIG, DRUCKTASTENBETATIGT
Order code 2 pole, push button actuated / Bestellcode 2polig, drucktastenbetatigt
Basic type Grundtyp Auxiliary contact (changeover) / Hilfskontakt (Wechsler) Shunt terminal / Nebenanschluss
P2 P1
P2
TA45
Without thermal overload protection Kein thermischer Uberstromschutz
*
P1 1110
6
5
6
5
12
Terminal type Anschlussart Snap-in type Schnappbefestigung
Quick connect terminal / Flachstecker Screw type terminal (lineside P1, P2) Schraubanschluss (Netzeingang P1, P2) Dimension / Massbild Page / Seite
*
77 ABK ABS 83 AHK AHS
*
78 AEK AES 84 AJK AJS
*
80 AUK AUS 86 ALK ALS
*
81 AXK AXS 87 APK APS
Push button gasket / Tastendichtung IP40 Push button gasket / Tastendichtung IP65 Flange type Flanschbefestigung Dimension / Massbild Page / Seite
Push button gasket / Tastendichtung IP40 Push button gasket / Tastendichtung IP65
Order example / Bestellbeispiel Basic type / Grundtyp
TA45- ABL T F J28 U2
Colours / Farben Switch front Schalter-Front T U V black / schwarz yellow / gelb grey / grau ON Button Taste EIN green / grun green / grun green / grun OFF Button TASTE AUS red / rot red / rot red / rot
Push button legend Drucktasten-Beschriftung Surface Oberflache F H K L M P R S T embossed / Relief printed / bedruckt printed / bedruckt printed / bedruckt printed / bedruckt printed / bedruckt printed / bedruckt printed / bedruckt printed / bedruckt Illustration Bild
0 l
Without thermal overload protection: code C00 Ohne thermischen Uberstromschutz: Code C00 Colour of print Druckfarbe With thermal overload protection: rated current In (A) Mit thermischem Uberstromschutz: Nennstrom In (A) In white / weiss black / schwarz white / weiss black / schwarz white / weiss black / schwarz white / weiss black / schwarz 0,05 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1,0 1,1 Z05 J01 J02 J03 J04 J05 J06 J07 J08 J09 J10 J11 1,2 1,3 1,4 1,5 1,6 1,7 1,8 1,9 2,0 2,1 2,2 2,3 J12 J13 J14 J15 J16 J17 J18 J19 J20 J21 J22 J23 2,5 2,8 3,0 3,5 4,0 4,5 5,0 6,0 6,5 7,0 7,5 8,0 J25 J28 030 035 040 045 050 060 065 070 075 080 9,0 10,0 11,0 12,0 13,0 14,0 15,0 16,0 17,0 18,0 19,0 20,0 090 100 110 120 130 140 150 160 170 180 190 200 Code In Code In Code In Code
I I ON l ON l
0 0 OFF OFF
0 0 0
l
0
l
OFF OFF
ON
ON
other rated currents on request / andere Stromwerte auf Anfrage
74
www.schurter.com
CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, PUSH BUTTON GERATESCHUTZSCHALTER, 2POLIG, DRUCKTASTENBETATIGT
TA45
1 pole thermal overload protection 1poliger thermischer Uberstromschutz
2 pole thermal overload protection 2poliger thermischer Uberstromschutz
*
P2 P1 P2 P1
P2
*
P1 1110 P2
* *
P1 1110
*
P2 P1 P2 P1
P2
*
P1 1110 P2
* *
P1 1110
6
3
6
3
3
5
6
12
6
3
5 12
4
3
6
4
3
4
3 12 6
4
3 5 12
5
*
77 ABL ABU 83 AHL AHU
*
78 AEL AEU 84 AJL AJU
*
77 ABM ABV 83 AHM AHV
*
78 AEM AEV 84 AJM AJV
*
80 AUL AUU 86 ALL ALU
*
81 AXL AXU 87 APL APU
*
77 AUM AUV 83 ALM ALV
*
78 AXM AXV 84 APM APV
*
77 ABN ABW 83 AHN AHW
*
78 AEN AEW 84 AJN AJW
*
77 ABP ABX 83 AHP AHX
*
78 AEP AEX 84 AJP AJX
*
80 AUN AUW 86 ALN ALW
*
81 AXN AXW 87 APN APW
*
80 AUP AUX 86 ALP ALX
*
81 AXP AXX 87 APP APX
Accessories see page 76 / Zubehor siehe Seite 76
with auxiliary contact mit Hilfskontakt
Without release / lock-out latch: code C0 Ohne Ausloser / Schaltsperre: Code C0 Undervoltage release Unterspannungs-Ausloser
P2 U< P1 P2 b U< P1 P2 ba U< P1
Detail see pages 52 - 54 Detail siehe Seiten 52 - 54 Remote trip release Fernausloser
P2 c P1
Mechanical lock-out latch Mechanische Schaltsperre
P2 P1
U*
E*
Z
A*
Code 2 3 4
Rated voltage Un Nennspannung Un AC (V) 240 230 120 AC / DC (V)
S0
* * *
* * *
* * *
* * *
* * * *
* * * *
* * * *
* * *
6 7 8 9
48 24 12 5
* Release U, E and A in combination with screw clamp terminals on request / Ausloser U, E und A in Kombination mit Schraubanschlussen auf Anfrage
www.schurter.com
75
CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, PUSH BUTTON GERATESCHUTZSCHALTER, 2POLIG, DRUCKTASTENBETATIGT
Order code accessories 2 pole, push button actuated Bestellcode Zubehor 2polig, drucktastenbetatigt
For subsequent fitting / Nachtraglich montierbar
TA45
AZZ05
Screw-on cover, 2 pole, IP65 Fronthaube schraubbar, 2polig, IP65
3
P1
5
AZZ51
Rear cover 2 pole, IP40 Beruhrungsschutz ruckseitig, 2polig, IP40
AZZ61
Flat gasket for snap-in type, 2 pole, IP54 Flachdichtung, 2polig, IP54 Flat gasket for snap-in type, 3 pole, IP54 Flachdichtung, 3polig, IP54 Flat gasket for screw-on type, 2 pole, IP54 Flachdichtung schraubbar, 2polig, IP54 Locking device black, 2 pole, safety-lock type Schliesskragen 2polig schwarz fur Vorhangeschloss Locking device yellow, 2 pole, safety-lock type Schliesskragen 2polig gelb fur Vorhangeschloss Locking device grey, 2 pole, safety-lock type Schliesskragen 2polig grau fur Vorhangeschloss Locking device black, 3 pole, safety-lock type Schliesskragen 3polig schwarz fur Vorhangeschloss Locking device yellow, 3 pole, safety-lock type Schliesskragen 3polig gelb fur Vorhangeschloss Locking device grey, 3 pole, safety-lock type Schliesskragen 3polig grau fur Vorhangeschloss
AZZ05
Order example Bestellbeispiel
AZZ62
AZZ63
AZZ71 AZZ72
3
P1 P1
5 3
5
AZZ73
AZZ81 AZZ82 AZZ83
Available accessories / Einsatzmoglichkeiten 2 pole version 2polige Ausfuhrung Snap-in type Schnappbefestigung AZZ05 AZZ51 AZZ61 AZZ62 AZZ63 AZZ71 AZZ72 AZZ73 AZZ81 AZZ82 AZZ83 Flange type Flanschbefestigung 2 pole version with auxiliary contact 2polige Ausfuhrung mit Hilfskontakt Snap-in type Schnappbefestigung Flange type Flanschbefestigung
* *
* * * *
*
*
* *
76
www.schurter.com
CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, PUSH BUTTON GERATESCHUTZSCHALTER, 2POLIG, DRUCKTASTENBETATIGT
Snap-in type and quick connect terminals / Schnappbefestigung und Flachsteckanschlusse
Basic type / Grundtyp
59 50
18.5
34 25
TA45
5
63
23.7
LINE
44.1
P1 a 3 5
10.6
34
5.3
26.7
8.4
10.8 21.5
Quick connect terminal / Flachstecker IEC 61210 A6,3-0,8
Undervoltage release, remote trip release / Unterspannungsauslosung, Fernauslosung
59 50 18.5
34 25
5
87
23.7
LINE
44.1
69
P1 a
3
5
1.5
Quick connect terminal Flachstecker IEC 61210 A6,3-0,8 15.5 21 Quick connect terminal / Flachstecker IEC 61210 A2,8-0,8
5.3
22 26.7
6.3 8.4
Mechanical lock-out latch / Mechanische Schaltsperre
59 50 18.5 34 25
5
6
10.6
34
75.7 50.6
23.7
LINE
44.1
P1 a 3 3 5
10.6
34
* max. Schalthub
2
8 (4.5) 3.5
8 (4.5) 3.5
22.8 5.3 26.7 8.4
10.8 17.5 19.5
Quick connect terminal Flachstecker IEC 61210 A6,3-0,8
2.8 2
2
2.5 *
5.5
www.schurter.com
77
7
CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, PUSH BUTTON GERATESCHUTZSCHALTER, 2POLIG, DRUCKTASTENBETATIGT
Snap-in type and screw clamp terminal / Schnappbefestigung und Schraubanschluss
Basic type / Grundtyp
Position on / Stellung ein 6
TA45
6
10.8
LINE
P1 a
3
5
10.8
Screw type M3,5x6 (Philips Form H) Maximum torque 1 Nm Klemmschraube M3,5x6 (Philips Form H) zulassiger Anzugsdrehmoment 1 Nm
Cut-out and pin-out / Montageoffnung und Anschlussbelegung
Cut-out / Montageoffnung a 1.0 1.5 2.0 2.5 3.0 4.0 5.0
21.7 - 0.0
+0.2
26.9
Pin-out / Anschlussbelegung b 44,5...45,0 44,5...45,0 44,7...45,2 44,7...45,2 44,8...45,3 44,9...45,4 45,0...45,5
U-Relais P2 P1 a
b
a (1.0 - 5.0)
c 4 3 6 5
b
Assemble Einbaurichtung
edge must be sharp scharfkantig
78
www.schurter.com
CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, PUSH BUTTON GERATESCHUTZSCHALTER, 2POLIG, DRUCKTASTENBETATIGT
Accessories / Zubehor
TA45
AZZ71 AZZ72
AZZ73 CBE not switchable / CBE nicht einschaltbar
89.4 21.6 28.1 20.1
CBE switchable / CBE einschaltbar
89.4 8.7 3.4
AZZ51
Snap-on fastener / Schnapphaken
54.6 x 28.3
65
86
104
20.9
7
www.schurter.com
79
CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, PUSH BUTTON GERATESCHUTZSCHALTER, 2POLIG, DRUCKTASTENBETATIGT
Snap-in type and quick connect terminals / Schnappbefestigung und Flachsteckanschlusse
Basic type with auxiliary contact / Grundtyp mit Hilfskontakt
59 50 45.5 25
TA45
18.5
5
63
52.4
23.7 43.6
7 10 11 12
9
10.6
34.7
10.8 11 33 Quick connect terminal Flachstecker IEC 61210 A6,3-0,8
34
5.3 11.6 7.6 7.5 8.4
Undervoltage release, remote trip release / Unterspannungsauslosung, Fernauslosung
59 50
45.5 25
18.5
5
52.4
87
23.7 43.6
7 10 11 12
9
69
10.6
34
34.7
15.5
1.5
6
9
21.5 33 Quick connect terminal Flachstecker IEC 61210 A6,3-0,8
22 6.3 5.3 11.6 7.6 7.5 8.4
Quick connect terminal Flachstecker IEC 61210 A2,8-0,8
Mechanical lock-out latch / Mechanische Schaltsperre
59 50 25
18.5
5
52.4 34.1
9
75.7 50.6
23.7
3
7 10 11
43.6
12
9
10.6
9
2
8 (4.5) 3.5
8 (4.5) 3.5
2.8 2
2
2.5
22.8 5.3 11.6 7.6 7.5 8.4
17.5
19.5
33
Quick connect terminal Flachstecker IEC 61210 A6,3-0,8
5.5
80
www.schurter.com
7
CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, PUSH BUTTON GERATESCHUTZSCHALTER, 2POLIG, DRUCKTASTENBETATIGT
Snap-in type and screw clamp terminal / Schnappbefestigung und Schraubanschluss
Basic type with auxiliary contact / Grundtyp mit Hilfskontakt
Position on / Stellung ein 6
TA45
6
10.8
9
11
7
10
11
12
10.8
Screw type M3,5x6 (Philips Form H) Maximum torque 1 Nm Klemmschraube M3,5x6 (Philips Form H) zulassiger Anzugsdrehmoment 1 Nm
11
Quick connect terminal Flachstecker DIN 46244 A6,3-0,8
Cut-out and pin-out / Montageoffnung und Anschlussbelegung
Cut-out / Montageoffnung a 1.0 1.5 2.0 2.5 3.0 4.0 5.0
33.2 - 0.0
+0.2
9
26.9
Pin-out / Anschlussbelegung b 44,5...45,0 44,5...45,0 44,7...45,2 44,7...45,2 44,8...45,3 44,9...45,4 45,0...45,5
P2 P1 a Auxiliary contact Hilfskontakt 10 a 4 3 6 11 12
b U-Relais
b
a (1.0 - 5.0)
Assemble Einbaurichtung
5
edge must be sharp scharfkantig
www.schurter.com
81
CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, PUSH BUTTON GERATESCHUTZSCHALTER, 2POLIG, DRUCKTASTENBETATIGT
Accessories / Zubehor
TA45
AZZ81
AZZ82
AZZ83 CBE not switchable / CBE nicht einschaltbar
CBE switchable / CBE einschaltbar
89.4 8.7 3.4 21.6
89.4 28.1 20.1
59
82
www.schurter.com
36.8 46.9
20.9
7
CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, PUSH BUTTON GERATESCHUTZSCHALTER, 2POLIG, DRUCKTASTENBETATIGT
Flange type and quick connect terminals / Flanschbefestigung und Flachsteckanschlusse
Basic type / Grundtyp
74 50 13 34 25
TA45
4
23.7
LINE
44.1
P1 a 3 5
5.3
26.7
8.4
10.6
43.3 39.3
63
10.8 21.5 Quick connect terminal / Flachstecker IEC 61210 A6,3-0,8
Undervoltage release, remote trip release / Unterspannungsauslosung, Fernauslosung
74 50 13 34 25
4
87
23.7
LINE
P1 a
3
5
74.5
44.1
1.5 Quick connect terminal Flachstecker IEC 61210 A6,3-0,8 15.5 21 Quick connect terminal / Flachstecker IEC 61210 A2,8-0,8
5.3
22 26.7
6.3 8.4
Mechanical lock-out latch / Mechanische Schaltsperre
74 50 13 34 25
4
6
10.6
43.3 39.3
75.5 56
43.3 39.3
* max. Schalthub
23.7
LINE
44.1
P1 a 3 3 5
10.6
2
8 (4.5) 3.5
8 (4.5) 3.5
22.8 5.3 26.7 8.4
10.8 17.5 19.5
Quick connect terminal Flachstecker IEC 61210 A6,3-0,8
2.8 2
2
2.5 *
5.5
www.schurter.com
83
7
CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, PUSH BUTTON GERATESCHUTZSCHALTER, 2POLIG, DRUCKTASTENBETATIGT
Flange type and screw clamp terminal / Flanschbefestigung und Schraubanschluss
Basic type / Grundtyp
Position on / Stellung ein 6
TA45
6
10.8
LINE
P1 a
3
5
10.8
Screw type M3,5x6 (Philips Form H) Maximum torque 1 Nm Klemmschraube M3,5x6 (Philips Form H) zulassiger Anzugsdrehmoment 1 Nm
Cut-out and pin-out / Montageoffnung und Anschlussbelegung
Cut-out / Montageoffnung Pin-out / Anschlussbelegung
P2 U-Relais P1 a
Installation from front and rear / Montage von vorne und hinten
4. 2
32.2
b
60 +0.2 50.5 - 0.0
c 4 3 6 25.2
+0.2 - 0.0
5
Installation from rear with AZZ05 cover / Montage von hinten mit AZZ05 Fronthaube
4.
60 +0.3 52.5 - 0.0 27.5 - 0.0
+0.3
84
www.schurter.com
2
CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, PUSH BUTTON GERATESCHUTZSCHALTER, 2POLIG, DRUCKTASTENBETATIGT
Accessories / Zubehor
TA45
AZZ05
72.6 62 60 52 17.3
34.8 34 27
O 4.5
O 3.8
AZZ51
Snap-on fastener / Schnapphaken
54.6 x 28.3
65
86
104
21.2
www.schurter.com
85
CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, PUSH BUTTON GERATESCHUTZSCHALTER, 2POLIG, DRUCKTASTENBETATIGT
Flange type and quick connect terminals / Flanschbefestigung und Flachsteckanschlusse
Basic type with auxiliary contact / Grundtyp mit Hilfskontakt
74 50 13 34 25
TA45
4
23.7 43.6
7 10 11 12
9
10.6
43.3 39.3
63
10.8 5.3 11.6 7.6 7.5 8.4 33
11
Quick connect terminal Flachstecker IEC 61210 A6,3-0,8
Undervoltage release, remote trip release / Unterspannungsauslosung, Fernauslosung
74 50 13 34 25
4
63
87
23.7 43.6
7 10 11 12
9
74.5
10.6
43.3 39.3
1.5
9 Quick connect terminal Flachstecker IEC 61210 A6,3-0,8 15.5 21.5 33 Quick connect terminal Flachstecker IEC 61210 A2,8-0,8 34 25
22
6.3
5.3 11.6 7.6 7.5 8.4
Mechanical lock-out latch / Mechanische Schaltsperre
74 50 13
4
6
9
75 50.6
Quick connect terminal Flachstecker IEC 61210 A6,3-0,8
43.3 39.3
* max. Schalthub
23.7
3 7 10 11
43.6
12
9
2 10.6 9
8 (4.5) 3.5
8 (4.5) 3.5
2.8 2
2
2.5 *
22.8 5.3 11.6 7.6 7.5 8.4
17.5 19.5 33
5.5
86
www.schurter.com
7
CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, PUSH BUTTON GERATESCHUTZSCHALTER, 2POLIG, DRUCKTASTENBETATIGT
Flange type and screw clamp terminal / Flanschbefestigung und Schraubanschluss
Basic type with auxiliary contact / Grundtyp mit Hilfskontakt
Position on / Stellung ein 6
TA45
6
9
7
10
11
12
10.8
Screw type M3,5x6 (Philips Form H) Maximum torque 1 Nm Klemmschraube M3,5x6 (Philips Form H) zulassiger Anzugsdrehmoment 1 Nm
11
Cut-out and pin-out / Montageoffnung und Anschlussbelegung
Cut-out / Montageoffnung Installation from rear / Montage von hinten
4. 2
9
32.3
Pin-out / Anschlussbelegung
P2 P1 a Auxiliary contact Hilfskontakt 10 a 4 11 12 3 6 5
b U-Relais 60 +0.2 50.5 - 0.0
25.2 - 0.0
+0.2
Installation from rear with AZZ05 cover / Montage von hinten mit AZZ05 Fronthaube
4. 2
60 +0.3 52.5 - 0.0 27.5 - 0.0
+0.3
www.schurter.com
87
CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, PUSH BUTTON GERATESCHUTZSCHALTER, 2POLIG, DRUCKTASTENBETATIGT
Accessories / Zubehor
TA45
AZZ05
72.6 62 60 52 17.3
34.8 34 27
O 4.5
O 3.8
88
www.schurter.com
21.2


▲Up To Search▲   

 
Price & Availability of TA45-APKVFZ05

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X